plustek@linuxhacker.org
plustek@linuxhacker.org
Hi,
The scanner already worked, but now i had to reinstall everything and now
i'm having problems again. Now i have SuSE 8.1. sane version: 1.0.8
No error messages to this point.
linux:/home/heiko/scanner/plustek_driver # make load
/sbin/modprobe pt_drv || exit 1
/lib/modules/2.4.19-4GB/misc/pt_drv.o: init_module: Success
Hint: insmod errors can be caused by incorrect module parameters, including
invalid IO or IRQ parameters.
You may find more information in syslog or the output from dmesg
/lib/modules/2.4.19-4GB/misc/pt_drv.o: insmod
/lib/modules/2.4.19-4GB/misc/pt_drv.o failed
/lib/modules/2.4.19-4GB/misc/pt_drv.o: insmod pt_drv failed
make: *** [load] Fehler 1
linux:/home/heiko/scanner/plustek_driver # dmesg
[...]
*********************************************
pt_drv: init_module()
pt_drv : driver version 0.41-6
ProcFsInitialize()
ptdrvInit(0)
Init settings done
ScanData = 0xcbb00000
Using fast I/O
Requested port at 0x378
Requested port (0x378) found
Port mode reported: (0x0047)
Port for device 0 registered
ptdrvOpen(port=0x378)
Try to claim the parport
parport-modi: SPP PS/2 EPP EPP(ECP) PS/2(ECP)
Using EPP-mode
Starting Scanner-Autodetection
************ DETECTP48xx ************
ModelSet4800()
modelInitPageSettings()
A4 set
ModelSet4800() done.
P48xxInitAsic()
DacInitialize()
ImageInitialize()
IOFuncInitialize()
IOInitialize()
MotorInitialize()
Dataport = 0x0378
Ctrlport = 0x037a
Test 0x55
Test 0xAA
Compare data=0x7e and status=0x1e, port=0x378
p48xxReadWriteTest()
Can't find your model, asic = 0x11
detectScannerConnection() returns -9031.
************* ASIC9800x *************
IOInitialize()
ASIC = 0x11
Unknown ASIC-ID
*** DETECTION DONE, result: -9020 ***
ptdrvClose()
MiscRestorePort()
- no need to restore portmode !
Releasing parport
ptdrvShutdown()
cleanup device 0
Port unregistered
ProcFsShutdown()
pt_drv: proc del 'info' root='pt_drv'
pt_drv: proc del 'pt_drv' root='/proc'
pt_drv : no device(s) detected, (-9020)
---------------------------------------------
linux:/home/heiko/scanner/plustek_driver #
Yesterday, the light switched on, but did not switch off. The next time i
tried it, the light did not switch on. I tried different configurations for
modules.conf, which i read in the mailing list archive.
What can i do?
Heiko.
plustek@linuxhacker.org