nanogui@linuxhacker.org

nanogui@linuxhacker.org


Subject: Re: new flnx + nano-X
From: Morten Rolland
Date: Tue, 10 Oct 2000 21:12:56 +0200

karl wrote:
> 
> Hello,
> 
> I have got the latest flnx and nano-X from CVS,
>  I get the error message on the console when I run the program:
> 
> client 1355: Wrong packet type 4877 (expected 22)
> client 1355: Wrong packet type 3084 (expected 22)
> client 1355: Wrong packet type 2317 (expected 22)
> client 1355: Wrong packet type 2310 (expected 22)
> client 1355: Wrong packet type 5135 (expected 22)
> client 1355: Wrong packet type 5140 (expected 22)
> client 1355: Wrong packet type 5140 (expected 22)
> client 1355: Wrong packet type 5140 (expected 22)
> client 1355: Wrong packet type 5140 (expected 22)
> client 1355: Wrong packet type 5140 (expected 22)
> client 1364: Wrong packet type 3598 (expected 17)
> client 1364: Wrong packet type 3598 (expected 17)
> client 1364: Wrong packet type 3598 (expected 17)

This looks very much like the protocol error in Nano-X
that we have been struggeling with for a while here at
Screen Media.

I have contacted Greg about how we should include our
fix into the standard soruce tree (we use a rather
old version of nano-X which is heavily patched, so
the patch will need some effort - therefore no
patch attached now, unfortunately...)

Best regards,
Morten Rolland, Screen Media, Norway.

nanogui@linuxhacker.org