plustek: unresolved symbols
Subject:
Re: Unresolved symbols
From:
"Jaeger, Gerhard" ####@####.####
Date:
21 Jun 2002 09:01:45 -0000
Message-Id: <200206210902.LAA10557@kah.ulm.sysgo.de>
Hi Karsten,
my mail address is still working, see signature. I changed
the reply address to reduce spam mails....
Well the problem is only, that scanimage doesn't find the scanner
pt_drv is fine, it's loaded (see lsmod) and your scanner is here,
see cat /proc/pt_drv/device0/info...
To see the real problem, I need the debug output of SANE:
open a shell
do a
export SANE_DEBUG_PLUSTEK=12
then call scanimage -L and send me the output (remember not only
reply to this mail ;-)))
Gerhard
P.S.: Sorry for the late reponse...
-------------------------
|gerhard AT gjaeger DOT de|
-------------------------
On Dienstag, 18. Juni 2002 23:13, Karsten Giesow wrote:
> Hi Gerhard,
>
> your mail-adresse is not working.
> If I'm using reply the mail came back.
[SNIP]
> During the installation I couldn't see something what is looking wrong.
> Please take a look at the messages from ls mod
> ---------
> nathan:/home/karsten # lsmod
> Module Size Used by Tainted: P
> pt_drv 111264 0 (unused)
[SNAP]
> ---------
> I have made also the test like in the test-file
> ---------
> nathan:/home/karsten # cat /proc/pt_drv/device0/info
> Model : 600P/6000P
> Portaddress : 0x378
> Portmode : BiDi (PS/2) (fast I/O, autodetect)
> Buttons : 0
> Warmuptime : 30s
> Lamp timeout: 180s
> mov-switch : 0
> I/O-delay : 0
> CCD-Type : NEC/TOSHIBA Type
> TPA : no