Hi ...

I found the problem was the timeout for the select, where waiting for
events.
The timout was clculatet on the old system-time (before set back) an was
to large.
I made a patch which checks system-clock-changes and calculates the
timeout
with the new time.

I hope the patch is usefull to others.

Regards
Robert