This looks like a communication problem so far.
You might set you parport in the BIOS to SPP and
if this works to EPP, do not use the ECP.

This may help.
Gerhard

On Wednesday, 13. March 2002 20:50, a.brotzmann wrote:
> Hi,
>
> I downloaded, compiled and installed the plustek-kernelmodule for my
> "Primax 4800 Direct" and everything went fine so far. But now I have
> problems to get it loaded:
>
> /sbin/modprobe pt_drv || exit 1
> /lib/modules/2.4.3-20mdk/misc/pt_drv.o: init_module: Success
> Hint: insmod errors can be caused by incorrect module parameters, including
> invalid IO or IRQ parameters
> /lib/modules/2.4.3-20mdk/misc/pt_drv.o: insmod
> /lib/modules/2.4.3-20mdk/misc/pt_drv.o failed
> /lib/modules/2.4.3-20mdk/misc/pt_drv.o: insmod pt_drv failed
> make: *** [load] Fehler 1
>
> and dmesg says:
>
> pt_drv: init_module()
> pt_drv : driver version 0.42-6
> ProcFsInitialize()
> ptdrvInit(0)
> Init settings done
> ScanData = 0xc05e8000
> Using fast I/O
> Requested port at 0x378
> Requested port (0x378) found
> Port mode reported: (0x005b)
> Port for device 0 registered
> ptdrvOpen(port=0x378)
> Try to claim the parport
> parport-modi: SPP PS/2 ECP PS/2(ECP)
> Using SPP-mode
> Trying faster mode...
> Attempting to set PS2 from ECPPS2 mode.
> Port is set to (ECP) PS2 bidirectional mode.
> Starting Scanner-Autodetection
> ************ DETECTP48xx ************
> ModelSet4800()
> modelInitPageSettings()
> A4 set
> ModelSet4800() done.
> P48xxInitAsic()
> DacInitialize()
> ImageInitialize()
> IOFuncInitialize()
> IOInitialize()
> MotorInitialize()
> Dataport = 0x0378
> Ctrlport = 0x037a
> Test 0x55
> Test 0xAA
> Compare data=0x78 and status=0x8, port=0x378
> p48xxReadWriteTest()
> Found a 96001 ASIC at Reg 0x13
> ModelSet4800()
> modelInitPageSettings()
> A4 set
> ModelSet4800() done.
> p48xxCheck4800Memory()
> Error in memory test at pos 256 (0 != 255)
> p48xxReadWriteTest()
> Found a 96001 ASIC at Reg 0x13
> ModelSet4800()
> modelInitPageSettings()
> A4 set
> ModelSet4800() done.
> p48xxCheck4800Memory()
> Error in memory test at pos 256 (0 != 255)
> p48xxReadWriteTest()
> Found a 96001 ASIC at Reg 0x13
> ModelSet4800()
> modelInitPageSettings()
> A4 set
> ModelSet4800() done.
> p48xxCheck4800Memory()
> Error in memory test at pos 256 (0 != 255)
> p48xxReadWriteTest()
> Found a 96001 ASIC at Reg 0x13
> ModelSet4800()
> modelInitPageSettings()
> A4 set
> ModelSet4800() done.
> p48xxCheck4800Memory()
> Error in memory test at pos 256 (0 != 255)
> p48xxReadWriteTest()
> Found a 96001 ASIC at Reg 0x13
> ModelSet4800()
> modelInitPageSettings()
> A4 set
> ModelSet4800() done.
> p48xxCheck4800Memory()
> Error in memory test at pos 256 (0 != 255)
> detectScannerConnection() returns -9020.
> ************* ASIC9800x *************
> IOInitialize()
> ASIC = 0xF0
> Unknown ASIC-ID
> *** DETECTION DONE, result: -9020 ***
> ptdrvClose()
> MiscRestorePort()
> Releasing parport
> ptdrvShutdown()
> cleanup device 0
> Port unregistered
> ProcFsShutdown()
> pt_drv: proc del 'info' root='pt_drv'
> pt_drv: proc del 'pt_drv' root='/proc'
> pt_drv : no device(s) detected, (-9020)
> --------------------------------------------
>
> I tryed the mov-switch and some other things to - without success. If I had
> any information about the protocol i would fix this problem by myself.
> Please help me either by giving me the nessesary information or fix it
> self. My scanner is the only thing that saves my Win-partition from being
> deleted.
>
> CU
> Andreas Brotzmann
> <http://www.andreas-brotzmann.de>
> ####@####.####
>
>
> ---------------------------------------------------------------------
> To unsubscribe, e-mail: ####@####.####
> For additional commands, e-mail: ####@####.####

Previous by date: 14 Mar 2002 20:42:24 -0000 Re: [sane-devel] I have opened my Genius HR6 usb id 2004 scanner..., Mario Giammarco
Next by date: 14 Mar 2002 20:42:24 -0000 Re: primax and plustek-module-42-5, a.brotzmann
Previous in thread: 14 Mar 2002 20:42:24 -0000 primax and plustek-module-42-5, a.brotzmann
Next in thread: 14 Mar 2002 20:42:24 -0000 Re: primax and plustek-module-42-5, a.brotzmann


Powered by ezmlm-browse 0.20.