On Fri, 5 Jul 2002 21:25:29 +0200 sjonnie wrote:
> there are high pitch "squeeek" sounds from the steppermoter on
> initiation/calibration.
I wonder if the calibration is working properly, because the scans from
my HP2200C look very underexposed to me, and have to have a big gamma
correction which messes up the overall colourspace.
> After that scanning is somewhat like two steps forward ,one step back
> (the table is almost shaking....) so no smooth movement even at 50
> dpi.
Mine does not do this, the scan is smooth. I have kernel 2.4.18-6mdk,
(Mandrake 8.2) which found the 2200 as soon as it was plugged in, no
problems. I wonder if you are loosing data in the USB transfer so the
scanner is forced to rescan?
> The lamp does not shut down after scanning (no matter what I put in the
> plustec.conf )
The Plustek backend tries twice to turn off the lamp, but fails:
[plustek] sane_exit
[plustek] Shutdown called (dev->fd=-1, /dev/usb/scanner0)
[plustek] Waiting for scanner-ready...
[plustek] Switching lamp off...
[plustek] LAMP-STATUS: 0x00000003
[plustek] Switching Lamp off
[plustek] LAMP-STATUS: 0x00000003
[plustek] Lamp-Timer stopped
Mike
--