Subject: D600 Calibration Problem?
From: "Mike Rothon" ####@####.####
Date: 4 Feb 2002 14:07:55 -0000
Message-Id: <014f01c1ad84$a41bfaf0$7d01a8c0@mike>

I have had some success with my D600 (I am guessing its a 30 bit) with both
primax_scan and primaxd except for the following:

primax_scan:
==========
Without the -o the scan head moves forward an inch from its current position
and then sits there. I have traced the code and the problem is in
read_calibration_data - the while condition is never met.

If I specify the -o switch the scan works fine (but is a little dark).

primaxd:
=======

If I change RESOLUTION to 600 and start a preview scan in SANE, the scanner
moves about an inch and then SANE locks up. I haven't traced this through,
but suspect the problem is similar, the code layout has changed slightly,
but the functionality is the same.

Leaving the RESOLUTION at 300 causes only a 1/4 of the page to be scanned
(not surprisingly) and the whole scan has a yellow tint.

All help is greatly appreciated,

Kind regards,

Mike.