primax: Thread: Re: pxscan...


[<<] [<] Page 1 of 1 [>] [>>]
Subject: Re: pxscan...
From: ####@####.#### (Schano)
Date: 5 Sep 2003 01:49:25 -0000
Message-Id: <3F57F478.D586EAE7@t-online.de>

Hello,

The pxscan is written for a 36-bit version of the scanner while the
primax-scan is for the 30-Bit version. But there is a sane version of to
the 30 bit version written by Andre Herms ####@####.####

So you must look whats your scanner is.

For the 30 bit d600 the latest SANE version was written by
####@####.#### but I do not know if this version is uploaded to
sourceforge. Please contact him.

The 30 Bit Version primax-scan needs an activated EPP-mode to the
printer port (Bios-setup). I do not know how the Sane version is
handling it but the primax-scan is able to switch an activated ECP-mode
to EPP.
While the windows Version is running under SPP as well as EPP. 

Best regards
Thomas

Michael Schmitt schrieb:
> 
> Hello folks!
> 
> Sorry for writing directly to you but I hope you can help me. I own a
> primax Colorado 600 but I do not get it working under Linux.
> 
> I tried to use the debianpakage and the newest sourcecode... it does not
> matter. If I run pxscan I allways get the same error:
> 
> "timeout: 7f -- we are in trouble"
> 
> And that error fills the whole screen endlessly till I press ctrl-c.
> Should I say that this scanner does work under Windows 2000? ;) So at
> least the scanner works. Is there anything I can do? As I think I do not
> need to load any modules... but I tried it with some modules too
> nevertheless (parport.o, parport_pc.o) :). The System is Debian 3.0
> unstable. Maybe the chipset is of interest too:
> 
> 00:00.0 Host bridge: Silicon Integrated Systems [SiS] 735 Host (rev 01)
> 00:01.0 PCI bridge: Silicon Integrated Systems [SiS] SiS 530 Virtual
> PCI-to-PCI bridge (AGP)
> 00:02.0 ISA bridge: Silicon Integrated Systems [SiS] 85C503/5513
> 
> A hint, help, guide, whatever would be very kind and would be
> appreciated!
> 
> greets Michael
> 
> --
> 
> HARDWORX - Netzwerke
> 
> Michael Schmitt
> Auf dem Weidweg 2
> 63579 Freigericht
> Telefon:  (+49) 06055 / 90 69 46
> Telefax:  (+49) 06055 / 90 69 45
> Mobil:    (+49) 0160 / 99 462 407
> E-Mail:   ####@####.####
> Web:      http://www.hardworx-online.net
[<<] [<] Page 1 of 1 [>] [>>]