plustek: Problem with OpticPro UT12 + Kernel 2.4.18
Subject:
Re: Problem with OpticPro UT12 + Kernel 2.4.18
From:
"Jaeger, Gerhard" ####@####.####
Date:
2 Jul 2002 16:07:11 -0000
Message-Id: <17PPzL-1LM1AGC@fmrl06.sul.t-online.com>
On Saturday, 29. June 2002 20:57, Rainer Unseld wrote:
> Hello,
>
> With kernel 2.4.10 from the SuSE 7.3 distribtion the Plustek driver
> 0_42_9) worked well with my UT12 USB scanner. When I installed kernel
> 2.4.18, I got several problems:
>
> 1. The scanner motor does not stop at the end of the scanner window but
> continues soem seconds, which creates a jamming noise.
>
> 2. Scanning is very slow. The scanner makes a short pause roughly every
> second,
>
> I went back to 2.4.10 and everything works well again.
>
> Regards
>
> Rainer Unseld
>
Hi Rainer,
the problem is the uhci! I noticed, that either using the module uhci or
usb-uhci causes this trouble, so simply check which one you're using
and then go ahead and use the other one instead...
Gerhard
-------------------------
gerhard AT gjaeger DOT de