plustek: Canon N670U stops during scanning


Previous by date: 31 Dec 2002 03:34:24 -0000 Driver plustek-0.45-TEST5 and Canon N650U, Edgar Kuchelmeister
Next by date: 31 Dec 2002 03:34:24 -0000 Re: Canon N670U stops during scanning, Capers
Previous in thread:
Next in thread: 31 Dec 2002 03:34:24 -0000 Re: Canon N670U stops during scanning, Capers

Subject: Canon N670U stops during scanning
From: Capers ####@####.####
Date: 31 Dec 2002 03:34:24 -0000
Message-Id: <20021231032653.WSHF22267.mta01-svc.ntlworld.com@[10.137.100.61]>

I've just obtained a Canon N670U scanner, and have been trying to use it with xsane. However, I'm having problems with the scanner locking up part way through a scan or preview scan.

I'm using a freshly compiled sane 1.0.9, with plustek 0.45-TEST5 and xsane 0.90 on a Red Hat 8 system.

The lockups mainly occur when calibration is switched on in plustek.conf, but can occur with no calibration. Lockups also occur if I set the gain values manually in the config file. 

Below is debug output from using xsane, where I've set the gain values manually, and calibration is switched off. The output is similar with calibration enabled.

[plustek] sane_start
[plustek] drvopen()
[plustek] usbDev_open(/dev/usb/scanner0,0x04A9-0x220D)
[plustek] Vendor ID=0x04A9, Product ID=0x220D
[plustek] usbio_DetectLM983x
[plustek] usbio_DetectLM983x: found LM9832/3
[plustek] Device description for >0x04A9-0x220D< found.
[plustek] usb_initDev(37,0x04a9,1)
[plustek] Device WAF: 0x0000004a
[plustek] Vendor adjusted to: >Canon<
[plustek] LAMP-STATUS: 0x00000000
[plustek] RESETTING REGISTERS(1)
[plustek] MISC I/O after RESET: 0x66, 0x16, 0x91
[plustek] usb_SetScanParameters()
[plustek] * HDPI: 4.000
[plustek] * XDPI=150, HDPI=4.000
[plustek] * DataPixelStart=75, LineEnd=75
[plustek] * Full Steps to Skip at Start = 0x0000
[plustek] usb_GetMCLKDivider()
[plustek] * Integration Time Adjust = 0 (HDPI=4.000,MCLKD=4.000)
[plustek] * Current MCLK Divider = 4.000000
[plustek] * PC-Rate mclkdiv=1.500000
[plustek] * MOTOR-Settings: PWM=0x08, PWM_DUTY=0x1f
[plustek] * PhyBytes   = 2
[plustek] * PhyLines   = 3221218396
[plustek] * TotalBytes = 2147441192
[plustek] * PL=295, coeffsize=216, scaler=3
[plustek] * PauseLimit = 295, [0x4e] = 0x91, [0x4f] = 0x01
[plustek] usb_SetScanParameters() done.
[plustek] usbDev_getCaps()
[plustek] usbDev_getLensInfo()
[plustek] wMAX=9600, WPHYMAX=1200
[plustek] scanmode = 3
[plustek] usbDev_getCropInfo()
[plustek] usb_GetImageInfo()
[plustek] PPL = 634
[plustek] LPA = 876
[plustek] BPL = 1902
[plustek] bright 0 contrast 0
[plustek] usbDev_setScanEnv()
[plustek] usb_SaveImageInfo()
[plustek] dwFlag = 0x00000800
[plustek] usb_GetImageInfo()
[plustek] Preview Mode set!
[plustek] Setting map[0] at 0x0813fec8
[plustek] Setting map[1] at 0x08143ec8
[plustek] Setting map[2] at 0x08147ec8
[plustek] usbDev_startScan()
[plustek] * HDPI: 8.000
[plustek] * XDPI=75, HDPI=8.000
[plustek] LAMP-STATUS: 0x00000000
[plustek] Switching Lamp on
[plustek] Warmup-Timer started
[plustek] LAMP-STATUS: 0x00000001
[plustek] Lamp-Timer stopped
[plustek] dwflag = 0x40000000 dwBytesPerLine = 1902, dwLinesPerScan = 876
[plustek] TIME START
[plustek] sane_start done
[dll] sane_get_parameters(handle=0x81305b0,params=0x8187b3c)
[plustek] reader process...
[plustek] reader_process started
[plustek] reader_process:starting to READ data (1666152 bytes)
[plustek] buf = 0x413f0008
[plustek] usbDev_readImage()
[plustek] usb_DoCalibration()
[plustek] goto shading position
[plustek] ShadingOriginY=30
[dll] sane_set_io_mode(handle=0x81305b0,nonblocking=1)
[plustek] sane_set_io_mode: non_blocking=1
[plustek] sane_set_io_mode done
[dll] sane_get_select_fd(handle=0x81305b0,fdp=0xbfffe7dc)
[plustek] sane_get_select_fd
[plustek] sane_get_select_fd done
[plustek] shading position reached
[plustek] SETMCLK[9/2], using entry 6: 2.000000, 600
[plustek] --> BYPASS
[plustek] SETMCLK[9/2], using entry 0: 6.000000, 75
[plustek] <-- BYPASS
[plustek] MOTOR: PWM=0x08, PWM_DUTY=0x33 0x45=0x13 0x48=0x00, 0x49=0xf2
[plustek] MCLK_FFW = 6 --> 0x0a
[plustek] Calibration done
-----------------------
[plustek] Static Gain:
[plustek] REG[0x3b] = 33
[plustek] REG[0x3c] = 35
[plustek] REG[0x3d] = 29
[plustek] Static Offset:
[plustek] REG[0x38] = 1
[plustek] REG[0x39] = 1
[plustek] REG[0x3a] = 1
[plustek] -----------------------
[plustek] calibration done.
[plustek] usb_SetScanParameters()
[plustek] * HDPI: 8.000
[plustek] * XDPI=75, HDPI=8.000
[plustek] * DataPixelStart=75, LineEnd=5147
[plustek] * Full Steps to Skip at Start = 0x0190
[plustek] usb_GetMCLKDivider()
[plustek] * Integration Time Adjust = 0 (HDPI=8.000,MCLKD=6.000)
[plustek] * Current MCLK Divider = 6.000000
[plustek] * PC-Rate mclkdiv=1.500000
[plustek] * MOTOR-Settings: PWM=0x08, PWM_DUTY=0x3f
[plustek] * PhyBytes   = 636
[plustek] * PhyLines   = 876
[plustek] * TotalBytes = 1671408
[plustek] * PL=294, coeffsize=216, scaler=3
[plustek] * PauseLimit = 294, [0x4e] = 0x91, [0x4f] = 0x01
[plustek] usb_SetScanParameters() done.
[plustek] Warmup: Waiting 45 seconds
[plustek] ImageProc is: ColorDuplicate8_2
[plustek] usb_ScanBegin()
[plustek] usb_MapDownload()
[plustek] brightness   = 0 -> 0
[plustek] contrast*100 = 0 -> 100
[plustek] usb_MapDownload() done.
[plustek] --> BYPASS
[plustek] Reading the data now!
[plustek] PhyDpi.x         = 75
[plustek] PhyDpi.y         = 75
[plustek] UserDpi.x        = 75
[plustek] UserDpi.y        = 75
[plustek] NumberOfScanBufs = 137
[plustek] LinesPerScanBufs = 4384
[plustek] dwPhyBytes       = 636
[plustek] dwPhyPixels      = 634
[plustek] dwTotalBytes     = 1671408
[plustek] dwPixels         = 634
[plustek] dwBytes          = 1902
[plustek] dwValidPixels    = 634
[plustek] dwBytesScanBuf   = 61056
[plustek] dwLinesDiscard   = 0
[plustek] dwLinesToSkip    = 1
[plustek] dwLinesUser      = 876
[plustek] dwBytesLine      = 1902
[plustek] usb_IsDataAvailableInDRAM()
[plustek] Data is available

After this, the scanner head moves some distance down the bed, and then stops, and I have to kill the process.

Is this a known problem, and are there any workarounds?
Leaving the calibration off gives very pink images, that aren't really usable.

If you need further information, just ask.

Thanks,

- Martyn Capewell