plustek: Colour-values in plustek scan compared to windows.


Previous by date: 14 Feb 2003 21:04:51 -0000 Epson 1260 and negatives, Kiraly Andras
Next by date: 14 Feb 2003 21:04:51 -0000 Epson 1260/Photo: negative scanning problems, Andrew Newman
Previous in thread: 14 Feb 2003 21:04:51 -0000 Colour-values in plustek scan compared to windows., GöranLarsson
Next in thread:

Subject: Re: Colour-values in plustek scan compared to windows.
From: Gerhard Jaeger ####@####.####
Date: 14 Feb 2003 21:04:51 -0000
Message-Id: <200302140822.22616.gerhard@gjaeger.de>

Hi Göran,

this is also a known issue, see the detection stuff in the log.
The device is detected as a OP600P and so the colors are 
switched...
The solution is to use the module switch mov=6 - see sane-plustek
man page for further details!

This should fix the problem,
  Gerhard


On Mittwoch, 12. Februar 2003 20:42, Göran Larsson wrote:
> HI!
>
> Box is 800Mhz Athlon 256MB ram NVIDIA video 30GB on two HD,Windows98se
> SuSE Linux 8.0. SANE-1.0.10 and plustek-sane-0.45-3.Scanner OpticPro 4800P.
> Maybe the plustek-sane is unnecessary but I didnt know.
>
> Made two scans one with windows and one with linux and GIMP.
> Measured the colours with Gimp-pipett on the same spots approximative.
> The result is as follows:
>
>            Windows                             Linux
>
> Resol.    75dpi                               78 dpi
> Brightn.  53 (0 - 100)                         2 (-50 - +50)
> Contrast  53   -"-                             2     -"-
>
> Place on     GIMP                              GIMP
> picture.   values of                          values of
>
>   ||       R   G    B                        R   G   B
>
>   \/
> Red       186  30   20                       27 198  26
>
> Blue       57  42   94                       32  31  112
>
> White     255 255  255                      255 255  255
>
> Yellow    244 190   37                      255 255   47
>
> Black       9   7    6                       15  22   21
>
> The windows scan looked like the original picture but the linux one
> was green on the red spots.
> For me it looks like swapping R and G would make sense.
>
> The problem is I dont know why,where and how.
> Maybe someone can help me?
>
> The /var/log/messages part of the linux scan (scan1734) is attached.
>
> Regards Göran Larsson.


Previous by date: 14 Feb 2003 21:04:51 -0000 Epson 1260 and negatives, Kiraly Andras
Next by date: 14 Feb 2003 21:04:51 -0000 Epson 1260/Photo: negative scanning problems, Andrew Newman
Previous in thread: 14 Feb 2003 21:04:51 -0000 Colour-values in plustek scan compared to windows., GöranLarsson
Next in thread:


Powered by ezmlm-browse 0.20.