plustek: how to put the lamp off ?
Subject:
Fwd: WG: how to put the lamp off ?
From:
Gerhard Jaeger ####@####.####
Date:
20 Jul 2004 11:08:55 +0100
Message-Id: <200407201208.46705.gerhard@gjaeger.de>
Hi,
please don't send the mails directly to me, use the list!!!
Datum: 20.07.2004 11:42
Von: Jacques Montier ####@####.####
[SNIPSNAP]
>
> Well, this does not work for me.
> After a scan, lamp is still on.
> Here is my modules.conf configuration :
> alias char-major-40 pt_drv
> options pt_drv port=0x378 forceMode=0 lOffonEnd=1
> mov=0 warmup=15 slowIO=0 lampoff=180
>
> Here is my plustek_pp.conf :
>
> [direct]
> device 0x378
>
> #
> # leave the default values as specified in
> /etc/modules.conf
> #
> option warmup -1
> option lOffOnEnd -1
> option lampOff -1
>
> [direct]
> device parport0
>
> my lamp should be off after 180 s ?...
> I tried to put lOffonEnd=0 to switch off the lamp
> after scanning, but it does not work either.
>
> thanks for your help.
When you're using the module, then your plustek_pp.conf will not work!
Can you please send the output of the following command to the list:
export SANE_DEBUG_PLUSTEK_PP=20 ; scanimage -L
You might also change
option lOffOnEnd 1
option lampOff 180
Ciao,
Gerhard