plustek: scanning range of a Optic pro 1236P on parrallel port
Subject:
Re: scanning range of a Optic pro 1236P on parrallel port
From:
Gerhard Jaeger ####@####.####
Date:
20 Aug 2004 14:17:54 +0100
Message-Id: <200408201511.42304.gerhard@gjaeger.de>
On Friday 13 August 2004 21:50, Christophe wrote:
> Hi,
>
> I have a question about my scanner Optic Pro 1236 P.
> I use Mdk 10Community with a 2.6 kernel and XSane 0.92. It sees the scanner
> as "a Plustec Optic Pro 1200-9600 Parallel port flattbed scanner on
> parport0" It works right "most of the time" but... it sometimes try to keep
> scanning as it get to the end of the scanning range, meaning a the bottom
> of the page. Then it cracks until I stop it.
>
> Do you have any idea what is wong in any config file ?
There's nothing wrong in the config file, as you can't controll the scan-bed
size there. The problem is, and always will be, that the driver itself
sometimes looses track of the sensor, and therefore it'll hit the scan-bed.
I'm afraid, that you can't do anything.
Ciao,
Gerhard